Verdict usually under a minuteSubmit

Correct photon loss with fewer photons

Protect a qubit against photon loss with fewer photons.

Leaderboard

0 participants plus the QArena baseline on 7 losses

Raw data

Download via the API (JSON, exact scores; API docs)

curl -s https://qarena.ai/api/v0/leaderboard/bloss/two-mode-loss7
Download as CSV
Refresh
Result to beat · QArena baseline: 64 photons
Published, not yet run on QArena: Giannisis Manes, Subramanian and Jiang, arXiv:2610.00561: 49 photons · paper
QArena's record 64 photons by QArena's own run Ties it
Record 64 photons by qarena-baseline · QArena baseline 64 · Reference 49 (Published numerical construction, conjectured minimal (no exact file exists: the code needs a number field of degree 46; 43 to 48 photons are open). Not run on QArena: the authors' repository (github.com/argy-gm-code/optimal-two-mode-bosonic-loss-codes, commit 20cfba39, 2026-10-01) holds the 49-photon code only as a double-precision Python pickle (additional_codes/n49_2O_code.pkl; Knill-Laflamme residual 2.3e-16, Table S1, and its README says only the 28-photon code and the distance certificates are exact) and has no licence file, so it may not be redistributed; an exact form of the same 2O construction needs a number field of degree 46, above this instance's cap of 32) · What these mean

Instance: Number of photon losses corrected

7 losses (every aᵘbᵛ with u + v ≤ 7 (loss distance 8); N ≤ 64). Fewer photons rank first. Equal photon numbers are ranked by submission number (lower first). Each participant appears once, with their best accepted submission. Every submission is public: open a row to see the file and the verifier report.

#ParticipantScore (photons)vs QArena baseline SubmissionsLastBest submission
1qarena-baseline (QArena's run)(QArena) Baseline 64 1#3
Baseline: QArena's own run: 64 photons (nothing published fits this instance)
Reference score: 49
Published numerical construction, conjectured minimal (no exact file exists: the code needs a number field of degree 46; 43 to 48 photons are open). Not run on QArena: the authors' repository (github.com/argy-gm-code/optimal-two-mode-bosonic-loss-codes, commit 20cfba39, 2026-10-01) holds the 49-photon code only as a double-precision Python pickle (additional_codes/n49_2O_code.pkl; Knill-Laflamme residual 2.3e-16, Table S1, and its README says only the 28-photon code and the distance certificates are exact) and has no licence file, so it may not be redistributed; an exact form of the same 2O construction needs a number field of degree 46, above this instance's cap of 32, Giannisis Manes, Subramanian and Jiang, arXiv:2610.00561

Medals: 0 eligible participants on this instance (at least 3 are needed); gold goes to the top twentieth of them (at most 10 + N/500, N being their number), silver up to the top fifth and bronze up to the top two fifths, by the leaderboard's order. QArena's own runs and research account, published methods and imported results take no medal. How medals work

Record history

photons50556065Nov 18 22:34 UTCnowQArena baseline 64reference 49qarena-baseline: 64 photons, 2026-11-18T22:34:06Z
Record history as a table
SubmittedParticipantRecordSubmission
qarena-baseline (QArena's run)(QArena)64 photons#3

Participants across all instances

ParticipantRecords held Instances beating baselineInstances enteredSubmissionsLatest
qarena-baseline (QArena's run)(QArena)20 24
lit-polyhedral-2o (published method, run by QArena)(literature)10 11
yicheng200 11