Verdict usually under a minuteSubmit

Decode logical circuits more accurately

Track errors across code patches linked by transversal CNOTs.

Leaderboard: 3-block GHZ d = 19 (Universal Quantum), half-full initialisation, p = 0.003 Hot

Result to beat · QArena baseline: 42 logical errors
Published, not yet run on QArena: Universal Quantum: 28.64 logical errors · paper
QArena's record 33 errors / 596,000 shots by yicheng Beats it: 1.2727× lower
#ParticipantScore (logical errors)vs QArena baselineSubmission
1yicheng331.2727× lower#18
2qarena-baseline (QArena's run)(QArena) Baseline42#17

Baseline: QArena's own run: 42 logical errors (nothing published fits this instance)

Full leaderboard

Instance: Patches, code distance and physical error rate

Overview

Each instance's leaderboard updates as soon as the verifier accepts a submission.
Every submission is public, but a logic-decoder file holds only the predicted flips for its own fresh batch: it shows neither your decoder nor how it works. Files are kept for 3 days, then deleted (the score stays; the best files of each cell's first 20 leaderboard rows are kept).

Task

Decode logical circuits. Each cell is a small fault-tolerant computation: two or eight rotated surface-code patches of distance d, joined by layers of transversal CNOTs, with one round of syndrome extraction before the first layer and one after every layer, under uniform circuit noise of strength p. A transversal CNOT copies errors from one patch to another, so the final logical value of a patch depends on errors that happened in other patches; a decoder has to follow them through the circuit. QArena publishes the Stim circuits, their detector error models and a layout file for every cell. For every ranked submission you request a fresh batch: a new set of shots, of the cell's fixed size, drawn from those circuits with a secret random seed. You download its detection events, submit the flips you predict for every patch's final logical in every shot, and the score is the exact number of shots you get wrong. The labels of a batch stay private on the QArena server and are never reused. Each cell has its own leaderboard; cells are not compared with each other. One cell is a published benchmark: Universal Quantum's three-block GHZ preparation at distance 19, on its released circuit, where its decoder fails on 100 of 2,080,768 shots (see Three-block GHZ cell below). One more circuit, which merges two distance-3 patches by lattice surgery, is offered as a practice set only, with no ranked cell (see Lattice-surgery practice set below).

CellPatches, dLayers L, rounds RpShots per batchDetectors D per experimentDownload
cnot2-surface7-p9p6e-4-v12, 732, 330.00096600,0003,168237.6 MB
cnot2-surface9-p1p4e-3-v12, 932, 330.0014400,0005,280264.0 MB
cnot2-surface11-p1p7e-3-v12, 1132, 330.0017260,0007,920257.4 MB
cnot2-surface13-p1p9e-3-v12, 1332, 330.0019190,00011,088263.3 MB
cnot8-surface7-p3p5e-4-v18, 716, 170.00035320,0006,528261.1 MB
cnot8-surface9-p5e-4-v18, 916, 170.0005196,00010,880266.6 MB
cnot8-surface11-p5p9e-4-v18, 1116, 170.00059130,00016,320265.2 MB
ghz3-half-surface19-p3e-3-v13 blocks, 192 (CNOT 0 → 1, 0 → 2), 40.003596,0003,600268.2 MB

Every cell has a practice set, answers public (the same circuits, 10,000 shots per experiment, detection events and labels public) for tuning and for checking a pipeline end to end; the GHZ cell's has 100,000 shots, because its decoders fail rarely. The lattice-surgery circuit has a practice set and no cell above. The p of each transversal-CNOT cell was set by a pilot so that the house decoder fails on between 0.1 % and 1 % of shots (see Baseline below); the eight-patch cells needed much lower p than planned. The GHZ cell keeps the paper's p = 0.003.

Circuits and data

Patches. Each patch is the rotated [[d2,1,d]] surface code with d2 data qubits and d2 − 1 measurement qubits. Its layout, checks, four-layer extraction CNOT order and logical strings are those of Stim 1.16.0's surface_code:rotated_memory_x and rotated_memory_z circuits at distance d. Patch j is the template shifted by j(2d + 4) in x; its qubit with template rank i (template indices sorted) has index j(2d2 − 1) + i. A transversal CNOT c → t applies CX from every data qubit of patch c to the data qubit at the same position in patch t.

Logical circuits. Two patches: 32 layers, CNOT 0 → 1 on even layers and 1 → 0 on odd layers. Eight patches: 16 layers of four disjoint CNOTs; at layer l patch j meets j XOR 2(l mod 3), smaller → larger when floor(l/3) is even and larger → smaller otherwise (64 logical CNOTs). Each extraction round has eight moments: ancilla reset (the data are prepared in the first one), H on the X ancillas, the four CNOT layers, H on the X ancillas, ancilla measurement. Each transversal layer is one moment. The last moment measures every data qubit.

Experiments. Every transversal-CNOT cell has two experiments with equal shot counts, X then Z (the lattice-surgery practice set has Z then T, see below). X: every data qubit starts in |+> and is measured in X at the end; Z: |0> and Z. Observable j (K = number of patches) is the final logical X (or Z) of patch j on the template's logical string; it is deterministic without noise, so the label is its noise-induced flip. A CNOT circuit on these product inputs never mixes the X and Z sectors: in the X experiment only Z errors flip an observable, and in the Z experiment only X errors. A cell with transversal H is the natural next release.

Noise. Uniform circuit noise with one parameter p: DEPOLARIZE2(p) after every CNOT (extraction and transversal), DEPOLARIZE1(p) after every H and on every idle live qubit in every moment (data qubits are always live; an ancilla is live from its reset to its measurement), and preparation and measurement flips with probability p (X_ERROR after R and before M, Z_ERROR after RX and before MX). Every fault location is independent.

Detectors. Detectors follow stabilizer propagation through each transversal layer. With s the check outcomes of round r − 1 and s′ those of round r, for a CNOT c → t between them and each check position:

D_X,c = s'_X,c + s_X,c + s_X,t      D_X,t = s'_X,t + s_X,t
D_Z,c = s'_Z,c + s_Z,c              D_Z,t = s'_Z,t + s_Z,t + s_Z,c

Round 0 has only detectors of the experiment's basis; the final data measurement closes that basis (data parity of each check plus its last outcome). So D = P(d2 − 1)(L + 1) per experiment. Order: for each round r = 0 .. L, each patch, each ancilla in the template's measurement order (round 0: experiment basis only); then the closure detectors, patch by patch. DETECTOR coordinates are (x, y, r) of the ancilla, with r = L + 1 for closure detectors.

Files (Data tab, every SHA-256 in the instance file): per experiment the circuit (X.stim), the full detector error model (X.dem, extracted with allow_gauge_detectors=False and not decomposed: the error mechanisms around a transversal CNOT include genuine hyperedges across two patches, kept as they are) and a layout (X.layout.json: the detector table (round, patch, check, type), every check's data support, the logical string and the CNOT schedule). Practice sets add X.dev.dets.b8 and X.dev.obs.b8. Detection events use Stim's b8 format: ceil(D/8) bytes per shot, bit i of the row is detector i, little-endian bit order.

Lattice-surgery practice set

surg2-xx-surface3-p8e-4-v1-dev (its files are in the folder surg2-xx-surface3-p8e-4-v1) is a frozen house reconstruction of the two-patch, distance-3 XX lattice surgery that Harper et al. ran on IBM's 120-qubit square-lattice processor ibm_phoenix (arXiv:2610.32347, Fig. 2 and Fig. 13). Qubits keep the device's numbers (q = 10 row + col; couplers join q to q ± 1 and q ± 10). Alice has data qubits 36 45 47 54 56 58 65 67 76 and Bob 63 72 74 81 83 85 92 94 103; the two patches touch with no qubits between them. As in the paper, qubit 55 is never used: in rounds 2 and 5 Alice measures the X check of the 55 plaquette as two gauge checks, X on 45 54 (ancilla 44) and X on 56 65 (ancilla 66), and her Z checks on 46 and 64 become gauges whose product is the stabilizer. Ancilla 64 serves Alice, and Bob's 73 measures his seam check Z on 63 74 in round 2 instead of its usual X check. Rounds 1 to 3 prepare the patches; rounds 4 to 6 merge them with the seam checks X on 54 63 (ancilla 53), Z on 54 63 65 74 (ancilla 64) and X on 65 74 76 85 (ancilla 75); Alice's 77 is retired after round 3, and in round 6 her 66 reads the X check on 67 76 that 77 read before. The data are then measured. The paper prints no gate order, so the house fixed one (layout file, gate_order): the first pair of per-type orders, in a fixed enumeration, that keeps every data qubit to one CNOT per layer and the circuit distance at 3 in both experiments. The distance is exactly 3: no one or two of each circuit's 6,542 Pauli faults flip the label with every detector silent, and three reset faults on one diagonal of a patch do (X after the reset of data qubits 36, 47 and 58 in Z, Z after the preparation of 63, 72 and 81 in T). The noise is the board's uniform circuit noise, not the paper's measured model.

Two experiments, each with one observable (bit 0 of each prediction byte; the other seven bits must be 0): Z prepares both patches in |0> and reads both in Z; its label is the flip of ZAZB. T teleports |+> from Bob to Alice: Bob starts in |+>, Alice in |0>, and after the merge Bob is read in Z and Alice in X; its label is the flip of m ⊕ XA, where m is the merge outcome (the product of the two X seam checks in round 4). In the ideal circuit m itself is a fair coin, so it is never a label; only m ⊕ XA is deterministic, and a decoder must decide whether the recorded m is wrong, which takes the three merged rounds into account (a chain of seam measurement errors through rounds 4 to 6 is a logical fault). Two variants were left out on purpose. Reading the Bell state in X gives the label m ⊕ XAXB, but that readout measures both X seam checks again, so the label is a sum of detectors and every decoder that explains the syndrome gets it right. Teleporting from Alice to Bob has circuit distance 2 under every gate order: Alice's 55 plaquette and her check on 67 76 are read only in rounds 2, 5 and 6, so a Z fault on her seam qubits before the merge meets a single detector. The layout file lists every detector's and the observable's measurement records.

Three-block GHZ cell (Universal Quantum)

ghz3-half-surface19-p3e-3-v1 is the three-block GHZ benchmark of Webber, Sadana, Lane, Robson and O'Rourke (Universal Quantum), arXiv:2610.26784, section 3, Fig. 5 and appendices D and E, at distance 19 with the half-full initialisation. Its circuit G.stim is the authors' released Stim sampling circuit GHZ_benchmark_d19_half_then_full_p0.003.stim, byte for byte (SHA-256 2329d5ae…6754, as in the archive's own index), from Zenodo record 23475403 (doi:10.5281/zenodo.23475403, version 1.0, file IRS_export.zip), © the authors, licensed under CC BY 4.0. QArena serves it unmodified; the DEM, the layout file and the practice set are derived from it by QArena with Stim 1.16.0. The paper says the circuit and error model are those of Cain et al. (arXiv:2505.13587), supplied to the authors.

Circuit. Three rotated surface-code blocks of distance 19 (qubits 0–720, 721–1441 and 1442–2162, the 361 data qubits of a block first). Block 0 starts in |+>, blocks 1 and 2 in |0>. One half round follows (block 0 measures only its Z checks, blocks 1 and 2 only their X checks: the initially indeterminate ones), then one full round on every block, the transversal CNOT 0 → 1, a full round on blocks 0 and 1, the transversal CNOT 0 → 2, a full round on blocks 0 and 2, and the destructive Z readout of every data qubit. The blocks extract one at a time, and the circuit keeps the supplied data-only waiting layers. Noise (appendix E.1): DEPOLARIZE2(0.003) after every CNOT, DEPOLARIZE1(0.003) after preparation and on idle locations, measurement flips with probability 0.003 on ancillas and on the final data readout.

Detectors and label. D = 3,600: every ancilla measurement and the readout parity of every Z check. The first outcomes of the initially indeterminate checks (540) are detectors with uniformly random values, as in the paper (gauge detectors; the DEM G.dem is extracted with allow_gauge_detectors=True and shows each of them as a probability-1/2 mechanism; the layout file lists them). K = 1: the observable is ZL of block 1 times ZL of block 2 at readout (the 19 data qubits of x = 19 in each block), which is deterministic in the GHZ state; the label is its noise-induced flip, bit 0 of each prediction byte. Stim refuses the DEM unless every probability-1/2 mechanism leaves the observable alone, so the label never depends on a random outcome.

Published result and batch size. With its decoder (IRS with correlated matching), Universal Quantum reports 100 failures in 2,080,768 shots of this circuit, 4.81 × 10-5 per shot (the data behind Fig. 5; the text rounds it to about 4.3 × 10-5, inside the data's 95 % interval 3.95 to 5.84 × 10-5). A batch has 596,000 shots, so that rate gives 596,000 × 100 / 2,080,768 = 28.64 expected errors per batch: the result to beat (a rate measured on Universal Quantum's own shots, not a file scored on a QArena batch). The paper puts reliable logical Pauli-product decoding (Cain et al.) at about 9 × 10-5 on the same circuit (read from a graph; about 54 per batch) and its own IRS with uncorrelated matching at 1.46 × 10-4 (101 in 692,224 shots; about 87 per batch). QArena's house decoder makes about 39 (below). One batch of a decoder as good as IRS varies by about √28.6 = 5.4 errors (19 %), and each submission is judged by its own count. A batch is 268.2 MB of detection events (596,000 shots is about the most that fits the site's 256 MiB limit on one batch) and must be answered within 2 hours of its draw: the house decoder needs 2 to 2.5 minutes on one desktop core (0.20 to 0.25 ms per shot).

The paper's ten-full-round variant (3.7 × 10-6 per shot, 100 failures in 26,977,018 shots) is not a cell: its circuit has 12,780 detectors (1,598 bytes per shot), so a batch within the 256 MiB limit holds at most 167,982 shots, 0.62 expected errors at that rate.

Fresh batches

Request a batch on the Data tab or with POST /api/v0/batch/logicdec/<instance>. The server samples every experiment of the cell from the published circuits with a new secret seed (Stim 1.16.0, compile_detector_sampler(seed).sample(shots, separate_observables=True, bit_packed=True)), stores the labels in its private directory and gives you the batch id and the download links (X.dets.b8 and Z.dets.b8; on the GHZ cell G.dets.b8). On the GHZ cell the server then flips the detectors of each gauge mechanism (the random first outcomes and the detectors that inherit them) together, shot by shot, with fresh random bits from the operating system: the distribution of detectors and label is unchanged, and the random first outcomes no longer carry the output of Stim's seeded generator. A batch must be answered within 2 hours of drawing it (every cell; a batch not answered in time is void and its files are deleted) and is scored once. Every batch of these cells is above 200 MB, so you may hold one open batch of this problem at a time (a batch stays open until its submission is accepted, so a file that is still queued keeps it open); you may draw 5 batches per problem per UTC day. A file the verifier rejects, or one that fails on the server, returns its batch, so a corrected file can still use it. To test a pipeline on data drawn exactly like a batch but with your own seed, use verifiers/logicdec_format.py sample from the verifier bundle (it needs pip install stim==1.16.0).

Submission file

{"format": "b8-base64-v1", "instance": "cnot2-surface7-p9p6e-4-v1", "batch": "<16 hex digits>",
 "predictions": "<base64>",
 "estimate": {"batch_ns": 61000000000, "cores": 8, "hardware": "..."}}      (estimate optional)

predictions is canonical standard base64 (no whitespace, = padding) of N rows of one byte, the experiments in instance order (X then Z; in the lattice-surgery practice set Z then T; the GHZ cell has the one experiment G), each in batch order. Bit j of a row (value 2j) is the predicted flip of observable j, the final logical of patch j. With two patches only bits 0 and 1 may be set; with eight patches the whole byte is used; in the lattice-surgery practice set and the GHZ cell only bit 0 (the experiment's one observable). The string has exactly 4·ceil(N/3) characters (800,000 for 600,000 shots; 794,668 for the GHZ cell's 596,000); a file may be at most 2 MiB. verifiers/logicdec_format.py pack turns raw b8 predictions, or one line of K characters 0/1 per shot, into this file. Practice sets take no batch. The estimate is the time your decoder took for the whole batch; it is shown but never ranked.

Validation

The verifier is the decoder board's standard-library scorer, used unchanged, with this board's instances and batch keys. It checks, before any label is read: strict JSON (no duplicate keys, NaN or Infinity; booleans are not numbers), exactly the keys above, the format string, the instance, a batch id of 16 lowercase hexadecimal digits on ranked instances (no batch on a practice set), the exact base64 length, the alphabet, canonical encoding and zero padding bits. A rejection therefore never depends on the labels. The server also refuses a batch that is not your own unused, unexpired batch of the same instance.

Scoring

E is the number of shots whose predicted row differs from the true row in any bit: a shot with several wrong patches counts once. Lower E ranks first; ties go to the lower submission number. The page shows E/N, the per-round rate E/(N R), a 95 % Wilson interval for the batch, the batch id and the number of batches the participant drew for the cell.

Statistical noise

Different submissions are scored on different shots. An error count varies by about √E between batches (1.7 to 3 % at the 1,150 to 3,450 errors the house decoder makes on the transversal-CNOT cells). Five draws a day for a week make a best of 35, which is about 2 standard deviations low by chance (4 to 6 % on these cells), more with several accounts, so decoders whose counts differ by less than about 8 % are not ordered by this table. The Wilson interval is descriptive and does not correct for choosing the best attempt. There is no weekly leadership in this first version. On the GHZ cell counts are small: a decoder as good as Universal Quantum's makes about 29 ± 5 errors per batch and the house about 39 ± 6, so one batch does not separate decoders within about 40 % of each other.

Baseline

The house decoder is our own implementation of logical-observable matching (the idea of Serra-Peralta et al., written with Stim 1.16.0 and PyMatching 2.4.0; it is not the LOMatching package). It decodes each observable k separately in k's final frame: with Sk(r) the patches whose round-r checks multiply into patch k's final checks (the backward light cone of the logical through the remaining layers), the virtual detector of check position a at round r is the XOR of the published detectors Dj(a, r) over j in Sk(r). Every error mechanism of the published DEM then becomes an edge or a boundary edge, and PyMatching decodes observable k as a memory experiment of one patch. It reads public files only and takes 0.02 to 0.16 ms per shot on one desktop core.

Its pilot failure rates at the registered p (50,000 to 70,000 shots per cell): 0.57, 0.81, 0.74, 0.67 % (two patches, d = 7 to 13) and 0.71, 0.93, 0.89 % (eight patches, d = 7 to 11), about 1,200 to 3,400 errors per batch. The pilot scanned p from the planned values down (planned 0.0012 to 0.0025 for two patches, 0.001 to 0.002 for eight). The two-patch cells took 0.8 times the planned p (d = 13 a little less); the eight-patch cells needed 0.29 to 0.35 times it, because in the eight-patch circuit the light cone of a logical soon covers up to all eight patches, and decoding one observable on the XOR of their detectors sees the noise of all of them. A decoder that keeps track of which patch an error came from, or that uses the correlations between observables, has room on these cells. A reference that runs PyMatching's correlated matching over all the observable frames at once (every error mechanism decomposed exactly into its edges in the frames it reaches; not a leaderboard row) makes 44 to 66 % fewer errors than the house decoder on the two-patch practice sets and 23 to 25 % fewer on the eight-patch ones:

Practice set, answers public (20,000 shots)HouseCorrelated referencePer-patch reference
2 patches, d = 7, p = 0.000961045014,036
2 patches, d = 9, p = 0.00141428014,844
2 patches, d = 11, p = 0.00171648115,007
2 patches, d = 13, p = 0.00191304414,969
8 patches, d = 7, p = 0.0003514811416,009
8 patches, d = 9, p = 0.000518514218,820
8 patches, d = 11, p = 0.0005916612419,588

Lattice-surgery practice set. The house decoder is PyMatching 2.4.0's correlated matching on the full detector error model (Stim's decomposition into edges; tools/logicdec_surgery.py, HouseDecoder). On the practice set's 20,000 shots (10,000 per experiment, p = 0.0008) it makes 197 errors (0.985 %; Z 134, T 63). Exact maximum likelihood (for each shot the more probable label value given the syndrome, summed exactly over every error configuration of the undecomposed model, by a dynamic program over the error mechanisms; a plain-numpy program checked against brute-force enumeration) makes 131 (Z 87, T 44). That is 0.66 times the house's errors. Maximum likelihood is the most accurate decoder possible for this noise model, so a decoder at the optimum lands near 131 here (on 20,000 shots a count varies by about √131 = 11, so counts within about 23 of each other are not distinguishable).

This circuit has no ranked cell because that optimum is cheap to reach. With a good elimination order no more than 13 (Z) or 15 (T) detectors are open at once, so exact maximum likelihood costs about 0.05 CPU seconds per shot, 8 core-hours for a 600,000-shot batch, and any participant could submit it on every batch; the top of a ranked cell would then be ordered by batch luck (about 3,990 ± 63 errors) and not by decoder quality. On a separate 600,000-shot probe draw (a public seed, not a served batch) the house decoder makes 5,739 errors, exact maximum likelihood 3,990 (0.70 times as many; Z 2,808 against 4,207, T 1,182 against 1,532), plain matching 6,387, and matching that ignores the merge (every detector that reads a seam check removed, so each patch is decoded as its own memory) 33,312. Use the practice set to calibrate a decoder against the house's 197 and the optimum's 131. The house's p = 0.0008 is the largest of 0.001, 0.0008 and 0.00065 at which its pilot failure rate is at most 1 % (0.94 %: 11,320 errors in 1,200,000 shots).

GHZ cell. The house decoder (tools/logicdec_ghz.py, HouseDecoder; our code, Stim 1.16.0 and PyMatching 2.4.0; the paper's decoder is not released) folds the random first outcomes away: each probability-1/2 mechanism of the DEM gets a pivot, its round-0 detector; every other detector it flips is replaced by its XOR with the pivot, and the pivots are dropped, which loses no information and leaves 3,060 deterministic detectors. Stim splits that model's error mechanisms into edges where it can; the rest (faults of block 0 copied by the two CNOTs, and faults at its first measurements) are split by block and check type, a single block-1 detector and a single block-2 detector forming one edge. PyMatching then runs correlated matching. On a public 20,480,000-shot dev batch (128 shards with published seeds, Derecho) it makes 1,325 errors, 6.47 × 10-5 per shot (95 % Wilson interval 6.13 to 6.83 × 10-5), about 39 per batch: 1.35 times Universal Quantum's rate and below the 9 × 10-5 of logical Pauli-product decoding. On the practice set it makes 6 errors in 100,000 shots. It takes 0.20 to 0.25 ms per shot on a desktop core (0.42 on a Derecho core). Decoding the circuit as one patch, with blocks 1 and 2 XORed together in the observable's frame, loses too much: about 3 × 10-3.

The per-patch reference projects each error mechanism onto one patch's own detectors; it is not fault tolerant here: a Z error on a target patch, measured there in the round before a CNOT, spreads to the control at the CNOT and flips the control's final X logical, but none of the control's own detectors change (their update rule includes the target's previous outcome). That reference fails on 70 to 98 % of practice-set shots.

For context, Cain et al. (arXiv:2505.13587) report thresholds of 0.493(1) % for a ten-patch, depth-14 transversal Clifford circuit and 0.593(1) % for memory, with a correlated decoder; their geometry, noise model and boundaries differ, so neither number is a reference score for this board.

What a public file reveals

Every submission is public, but a file holds only the predicted flips for its own batch: it shows neither your decoder nor how it works, and it says nothing about any other batch. Files are kept for 3 days and then deleted (the score stays); the best file of every leaderboard row is kept for good, so every row can be downloaded.

Application

Fault-tolerant algorithms run logical gates, and transversal gates are the cheapest ones in the surface code, but they spread errors between patches. Decoding them well (jointly, with correlations across patches and observables) decides how many rounds of syndrome extraction a computation needs between gates, and therefore its time and qubit cost.

Where verification runs

Verifications of this board run on the first lane of this list that is up and has room: the Mac mini, then CU Boulder's Alpine, then NCAR Derecho. A lane that is down, full or slow passes the file to the next one automatically, with the same verifier version; the limits of one verification are 15 s of CPU, 60 s of wall time and 512 MB of memory on the Mac mini, and 30 s of CPU, 120 s of wall time and 512 MB of memory on CU Boulder's Alpine and NCAR Derecho (2 times the board's own CPU and wall time on the other lanes, because their processors are slower); the result goes to QArena only. On the Mac mini the verifier reads the hidden labels where QArena's server keeps them; they do not leave it. Its hidden labels go only to the one Alpine job that needs them (a fresh batch's labels after the file's format has passed, bb-cycle's stored house evaluation with the claim), never to a log, and are deleted with the job's folder. Its hidden labels go only to the one Derecho job that needs them (a fresh batch's labels after the file's format has passed, bb-cycle's stored house evaluation with the claim), never to a log, and are deleted with the job's folder.

Current records

InstanceBaselineRecord (logical errors) Reference scoreRecord holderStatus
3-block GHZ d = 19 (Universal Quantum), half-full initialisation, p = 0.003 Hot
596,000 fresh shots per submission (268.2 MB of detection events, a prediction file of about 0.79 MB), private labels; one experiment: Universal Quantum's released circuit byte for byte, three d = 19 surface-code blocks, |+>|0>|0>, a half round then a full round, transversal CNOTs 0 -> 1 and 0 -> 2, Z readout; 3,600 detectors (540 random first outcomes among them), 1 observable (Z_L of block 1 times Z_L of block 2), 2,163 qubits
42
QArena's run
3328.64
Published: Universal Quantum's IRS decoder (correlated matching) on this circuit, 28.64 expected logical errors per 596,000-shot batch, the result to beat: 100 failures in 2,080,768 shots (4.81e-05 per shot; the data of the paper's Fig. 5, whose text rounds it to about 4.3 x 10^-5), so 596,000 x 100/2,080,768; a rate measured on Universal Quantum's own shots, not a file scored on a QArena batch. Not run on QArena: the decoder is not released (Zenodo 23475403, CC BY 4.0, holds the Stim circuits and the CSV results, whose row uq_correlated_half, d = 19, gives these 100 errors in 2,080,768 shots; the paper links no decoder code), and rebuilding IRS from the paper (iterated local matching with propagated detector updates and a prior-informed first pass) and decoding a 596,000-shot batch was beyond the pre-launch time box, Webber, Sadana, Lane, Robson and O'Rourke (Universal Quantum), arXiv:2610.26784, Fig. 5 and its data (Zenodo 23475403)
yichengBeats the baseline
2 patches d = 7, p = 0.00096
600,000 fresh shots per submission (237.6 MB of detection events), private labels; X and Z experiments, 32 transversal CNOT layers, 33 rounds, 3,168 detectors, 2 observables, 194 qubits
3,573
QArena's run
3,573–
No reference score: published rates come from other circuits
qarena-baseline (QArena's run)(QArena)Baseline not beaten
2 patches d = 9, p = 0.0014
400,000 fresh shots per submission (264.0 MB of detection events), private labels; X and Z experiments, 32 transversal CNOT layers, 33 rounds, 5,280 detectors, 2 observables, 322 qubits
3,279
QArena's run
3,279–
No reference score: published rates come from other circuits
qarena-baseline (QArena's run)(QArena)Baseline not beaten
2 patches d = 11, p = 0.0017
260,000 fresh shots per submission (257.4 MB of detection events), private labels; X and Z experiments, 32 transversal CNOT layers, 33 rounds, 7,920 detectors, 2 observables, 482 qubits
2,059
QArena's run
2,059–
No reference score: published rates come from other circuits
qarena-baseline (QArena's run)(QArena)Baseline not beaten
2 patches d = 13, p = 0.0019
190,000 fresh shots per submission (263.3 MB of detection events), private labels; X and Z experiments, 32 transversal CNOT layers, 33 rounds, 11,088 detectors, 2 observables, 674 qubits
1,273
QArena's run
1,273–
No reference score: published rates come from other circuits
qarena-baseline (QArena's run)(QArena)Baseline not beaten
8 patches d = 7, p = 0.00035
320,000 fresh shots per submission (261.1 MB of detection events), private labels; X and Z experiments, 16 transversal CNOT layers, 17 rounds, 6,528 detectors, 8 observables, 776 qubits
2,300
QArena's run
2,300–
No reference score: published rates come from other circuits
qarena-baseline (QArena's run)(QArena)Baseline not beaten
8 patches d = 9, p = 0.0005
196,000 fresh shots per submission (266.6 MB of detection events), private labels; X and Z experiments, 16 transversal CNOT layers, 17 rounds, 10,880 detectors, 8 observables, 1,288 qubits
1,948
QArena's run
1,948–
No reference score: published rates come from other circuits
qarena-baseline (QArena's run)(QArena)Baseline not beaten
8 patches d = 11, p = 0.00059
130,000 fresh shots per submission (265.2 MB of detection events), private labels; X and Z experiments, 16 transversal CNOT layers, 17 rounds, 16,320 detectors, 8 observables, 1,928 qubits
1,202
QArena's run
1,202–
No reference score: published rates come from other circuits
qarena-baseline (QArena's run)(QArena)Baseline not beaten
2 patches d = 7, p = 0.00096 (practice set, answers public)
practice instance, 20,000 shots with public labels; X and Z experiments, 32 transversal CNOT layers, 33 rounds, 3,168 detectors, 2 observables, 194 qubits
104
QArena's run
104–
Practice set, answers public
qarena-baseline (QArena's run)(QArena)Baseline not beaten
2 patches d = 9, p = 0.0014 (practice set, answers public)
practice instance, 20,000 shots with public labels; X and Z experiments, 32 transversal CNOT layers, 33 rounds, 5,280 detectors, 2 observables, 322 qubits
142
QArena's run
142–
Practice set, answers public
qarena-baseline (QArena's run)(QArena)Baseline not beaten
2 patches d = 11, p = 0.0017 (practice set, answers public)
practice instance, 20,000 shots with public labels; X and Z experiments, 32 transversal CNOT layers, 33 rounds, 7,920 detectors, 2 observables, 482 qubits
164
QArena's run
164–
Practice set, answers public
qarena-baseline (QArena's run)(QArena)Baseline not beaten
2 patches d = 13, p = 0.0019 (practice set, answers public)
practice instance, 20,000 shots with public labels; X and Z experiments, 32 transversal CNOT layers, 33 rounds, 11,088 detectors, 2 observables, 674 qubits
130
QArena's run
130–
Practice set, answers public
qarena-baseline (QArena's run)(QArena)Baseline not beaten
8 patches d = 7, p = 0.00035 (practice set, answers public)
practice instance, 20,000 shots with public labels; X and Z experiments, 16 transversal CNOT layers, 17 rounds, 6,528 detectors, 8 observables, 776 qubits
148
QArena's run
148–
Practice set, answers public
qarena-baseline (QArena's run)(QArena)Baseline not beaten
8 patches d = 9, p = 0.0005 (practice set, answers public)
practice instance, 20,000 shots with public labels; X and Z experiments, 16 transversal CNOT layers, 17 rounds, 10,880 detectors, 8 observables, 1,288 qubits
185
QArena's run
185–
Practice set, answers public
qarena-baseline (QArena's run)(QArena)Baseline not beaten
8 patches d = 11, p = 0.00059 (practice set, answers public)
practice instance, 20,000 shots with public labels; X and Z experiments, 16 transversal CNOT layers, 17 rounds, 16,320 detectors, 8 observables, 1,928 qubits
166
QArena's run
166–
Practice set, answers public
qarena-baseline (QArena's run)(QArena)Baseline not beaten
XX lattice surgery d = 3 on ibm_phoenix, p = 0.0008 (practice set, answers public)
practice instance, 20,000 shots with public labels; Z and T experiments (one observable each), XX lattice surgery of two d = 3 patches, 6 rounds, 78 detectors, 35 qubits of ibm_phoenix (qubit 55 excluded)
197
QArena's run
197–
Practice set, answers public
qarena-baseline (QArena's run)(QArena)Baseline not beaten
3-block GHZ d = 19 (Universal Quantum), half-full initialisation, p = 0.003 (practice set, answers public)
practice instance, 100,000 shots with public labels; the ranked cell's circuit, 3,600 detectors, 1 observable, 2,163 qubits
6
QArena's run
6–
Practice set, answers public
qarena-baseline (QArena's run)(QArena)Baseline not beaten

The baseline of an instance is its published result where there is one (the hot instance's famous result, a cited published reference, or a published result or method on its leaderboard), else QArena's own run. Reference scores come from cited papers or derived constructions.

Record changes

Each card is a strict record improvement on a ranked instance. Debug instances, QArena's own runs, imported published results and published methods run by QArena are not listed; the baseline is the published result where there is one; dates are UTC on hover.

No participant record yet on the headline instance of Logical circuit decoding, 2 patches d = 7, p = 0.00096: 3,573 errors / 600,000 shots (0.596 % per shot on its own batch) by QArena baseline.