Verdict usually under a minuteSubmit

Selected-CI variational energy

A lower variational energy at a fixed number of determinants means a better choice of determinants and coefficients, the quantity selected-CI codes and sample-based quantum diagonalization (SQD) on quantum hardware both produce. A record is a file anyone can re-score exactly in seconds, so a quantum team can compare its own vector of the same size with it on the same Hamiltonian. On the Hubbard cells the vector is a compact starting state in the lattice's own basis for a phase-estimation run on QuEra's 8 x 8 workload.

Leaderboard

1 participant plus the QArena baseline on N2/STO-3G, 14 electrons in 10 orbitals (debug)

Raw data

Download via the API (JSON, exact scores; API docs)

curl -s https://qarena.ai/api/v0/leaderboard/sciup/sci-n2-sto3g
Download as CSV
Refresh
Result to beat · QArena baseline: -107,677,339 µHa or µt
QArena's record -107,677,339 µHa or µt by QArena's own run Ties it
Record -107,677,339 µHa or µt by qarena-baseline · QArena baseline -107,677,339 · Reference -107,677,339 (Full CI energy -107.6773397492 Ha (PySCF on this file; floating point, so a numerical benchmark). QArena's integer FCI vector reaches it to 10 decimals; by this floating-point value no vector can show fewer micro-hartree (that needs 0.25 micro-hartree more), which is numerical evidence, not a proof. The RHF determinant alone scores -107.4877839280 Ha) · What these mean

Instance: Hamiltonian and cap

This is a debug instance for checking a pipeline end to end; its table is not a ranking.

N2/STO-3G, 14 electrons in 10 orbitals (debug) (debug cell: N2 at 1.2 Å in the STO-3G basis, the 10 RHF orbitals, written by QArena with PySCF; the full space has 14,400 determinants, so the exact ground state fits under the cap of 16,384). Lower energy in whole micro-hartree ranks first: the exact Rayleigh quotient E rounded up to the micro-hartree, as the board shows it (it also shows E in hartree to 10 decimals; the exact fraction is in each result). Within the same micro-hartree the lower submission number ranks first, so a copy of a record with a coefficient changed or a small determinant dropped cannot pass it; the number of determinants (the merged support) is shown, not ranked. On the two Hubbard cells the energy unit is the hopping t, so the same rule reads in micro-t (µt). Each participant appears once, with their best accepted submission. Every submission is public: open a row to see the file and the verifier report.

#ParticipantScore (µHa or µt)vs QArena baseline SubmissionsLastBest submission
1qarena-baseline (QArena's run)(QArena) Baseline -107,677,339
Energy (Ha, or t on the Hubbard cells; 10 decimals) -107.6773397492 · Determinants 2844
1#3
2yicheng
Exact FCI ground state over the full 14,400-determinant space: own string-based…
-107,677,339
Energy (Ha, or t on the Hubbard cells; 10 decimals) -107.6773397492 · Determinants 2844
1#5
Baseline: QArena's own run: -107,677,339 µHa or µt (nothing published fits this instance)

Debug instances give no medal.

Record history

µHa or µt-1.07677e+08-1.07677e+08-1.07677e+08-1.07677e+08-1.07677e+08Nov 21 04:30 UTCnowQArena baseline -107,677,339qarena-baseline: -107,677,339 µHa or µt, 2026-11-21T04:30:28Z
Record history as a table
SubmittedParticipantRecordSubmission
qarena-baseline (QArena's run)(QArena)-107,677,339 µHa or µt#3

Participants across all instances

ParticipantRecords held Instances beating baselineInstances enteredSubmissionsLatest
qarena-baseline (QArena's run)(QArena)40 45
qarena_auto_research11 11
yicheng01 12
lit-kumar-bs-uhf (published method, run by QArena)(literature)00 11